fbpx

Local Reviews
for Delaware, OH

Lewis Center-Powell Heating & Air Rated 4.9 out of 5 stars based on 15 customer reviews

Map of Delaware, OH

Service




Review of Lewis Center-Powell Heating & Air


Map of Delaware, OH

Customer




Review of Lewis Center-Powell Heating & Air


Map of Delaware, OH

Fantastic customer service, better results




Review of Lewis Center-Powell Heating & Air

They were curtious, prompt and extremely friendly. We had them clean our vents and replace our furnace for much less than other places. I would highly recommend them for all your heating and air needs.


Map of Delaware, OH

Service with a Smile




Review of Lewis Center-Powell Heating & Air

Friendly and informative phone call and service technician.


Map of Delaware, OH

Great service




Review of Lewis Center-Powell Heating & Air

Very professional


Map of Delaware, OH

Service was excelent and people were very courteous..




Review of Lewis Center-Powell Heating & Air


Map of Delaware, OH

cheapest repairs in delaware




Review of Lewis Center-Powell Heating & Air


Map of Delaware, OH

Great Fast Service!




Review of Lewis Center-Powell Heating & Air


Map of Delaware, OH

Knowledge fast and great service




Review of Lewis Center-Powell Heating & Air

Overall happy. Installation was scheduled quick.


Map of Delaware, OH

Great customer service




Review of Lewis Center-Powell Heating & Air

I called on the coldest day of the year and you were the only company that could come out the same day and fix my heat...awesome.


Jacob M.

Jacob M.

Upon arrival I found the unit was a system we no longer service.

Near Hickory Ln, Delaware, OH 43015
Jacob M.

Jacob M.

Upon arrival I found the unit was a type of system that we no longer service.

Near Hickory Ln, Delaware, OH 43015
Robby D.

Robby D.

I installed a Carrier 96% Two-Stage 60,000 BTU Gas Furnace and a Carrier 17 SEER 2 STAGE 3 Ton Air Conditioner.

Near Brenden Loop, Delaware, OH 43015
Delaware, OH - I installed a Carrier 96% Two-Stage 60,000 BTU Gas Furnace and a Carrier 17 SEER 2 STAGE 3 Ton Air Conditioner.
Sarah F.

Sarah F.

Upon arrival I found the outdoor unit had stopped working due to a pressure switch lockout. After running diagnostics, I found the customer had replaced the filter a couple days ago and due to everything in the system working and the customer describing the state of the previous filter, I determined the previous filter was extremely dirty and caused the pressure switch lockout.

Near Piatt Rd, Delaware, OH 43015
Delaware, OH - Upon arrival I found the outdoor unit had stopped working due to a pressure switch lockout. After running diagnostics, I found the customer had replaced the filter a couple days ago and due to everything in the system working and the customer describing the state of the previous filter, I determined the previous filter was extremely dirty and caused the pressure switch lockout.
Jacob M.

Jacob M.

I pulled the burner assembly out and scrubbed clean with stainless steel brush to allow for maximum passage for combustion gas. I suggest either replacing smart valve or replacing furnace. 2002 ICP gas system heating properly at this time.

Near E William St, Delaware, OH 43015
Delaware, OH - I pulled the burner assembly out and scrubbed clean with stainless steel brush to allow for maximum passage for combustion gas. I suggest either replacing smart valve or replacing furnace. 2002 ICP gas system heating properly at this time.
Jacob M.

Jacob M.

I pulled and cleaned the flame sensor. I recommend that customer either have evaporator coil and blower motor cleaned or consider replacing 2001 Trane gas furnace. System is operating at time of departure.

Near Rockmill St, Delaware, OH 43015
Delaware, OH - I pulled and cleaned the flame sensor. I recommend that customer either have evaporator coil and blower motor cleaned or consider replacing 2001 Trane gas furnace. System is operating at time of departure.
Dawn M.

Dawn M.

I was unable to recreate the noise the customer said they heard. I did fine the Goodman logo was loose on the furnace and removed it. I adjusted the gas pressure to within specs. System was operational upon departure.

Near Mcnamara Loop, Delaware, OH 43015
Delaware, OH - I was unable to recreate the noise the customer said they heard. I did fine the Goodman logo was loose on the furnace and removed it. I adjusted the gas pressure to within specs. System was operational upon departure.
Jacob M.

Jacob M.

I found the ignitor had signs of being close to failure, I also pulled and cleaned the flame sensor to help it run efficiently. System operating as it should upon departure.

Near Thistle Dr, Delaware, OH 43015
Delaware, OH - I found the ignitor had signs of being close to failure, I also pulled and cleaned the flame sensor to help it run efficiently. System operating as it should upon departure.
Jacob M.

Jacob M.

I cycled 1999 Bryant gas system and found that the ignitor has failed. I replaced with Carrier (W Shaped) ignitor. Everything operating properly at time of departure.

Near Jericho Pl, Delaware, OH 43015
Delaware, OH - I cycled 1999 Bryant gas system and found that the ignitor has failed. I replaced with Carrier (W Shaped) ignitor. Everything operating properly at time of departure.
Jacob M.

Jacob M.

I found 2020 Trane gas system flashing 9 times indicating an ignition issue. I explained to customer that igniter has failed and went over repair/replace options. I replaced ignitor with glow fly. System is heating/operating at this time.

Near Saratoga St, Delaware, OH 43015
Delaware, OH - I found 2020 Trane gas system flashing 9 times indicating an ignition issue. I explained to customer that igniter has failed and went over repair/replace options. I replaced ignitor with glow fly. System is heating/operating at this time.